ITC | PLTC

Millions of Possibilities. Custom-Configured Cost Savings.

NWI's ITC/PLTC exposed-run industrial instrument and control wiring is engineered to meet application requirements for factory floor automation equipment, material handling, sensors and transducers, process controls and other applications. Northwire also offers all major instrumentation network protocols such as FOUNDATION™ fieldbus, ODVA™ DeviceNet™, and Profibus™ DP and PA. Enjoy lower installation costs, utilizing the ITC | PLTC exposed run amendment to the NEC®, eliminating the need for conduit.

 

 ITC-GPITC-GP (ER)ITC-RSITC-RS (ER)ITC-DB (ER)ITITC-Extreme
General PurposeGeneral Purpose/
Exposed Run
Rugged ServiceRugged Service/
Exposed Run
D irect Burial/
Exposed Run
Extreme
FEATURES            
Signal -
Control -
Instrumentation -
ATTRIBUTES            
Low-Temperature Rating ≤-30°C ≤-30°C ≤-40°C ≤-40°C ≤-30°C ≤-60°C
High-Temperature Rating 105°C 105°C 105°C 105°C 105°C 105°C
Cold Bend ≤-20°C ≤-20°C ≤-20°C ≤-20°C ≤-20°C ≤-20°C
Impact Resistant
Crush Resistant
Flame Resistant FT4/IEEE 1202,
UL 1685 Vertical-Tray
FT4/IEEE 1202,
UL 1685 Vertical-Tray
FT4/IEEE 1202,
UL 1685 Vertical-Tray
FT4/IEEE 1202,
UL 1685 Vertical-Tray
FT4/IEEE 1202,
UL 1685 Vertical-Tray
UL 1685 Vertical-Tray
Exposed Run Rated - NEC® 727.4(5) - NEC® 727.4(5) NEC® 727.4(5) -
Direct Burial Rated - - NEC® 727.4(8) -
Hazardous Class I, Div 2 Class I, Div 2 Class I, Div 2 Class I, Div 2/ Class I, Div 2 Class I, Div 2
Wet Location Use
Oil Resistant
Chemical Resistant
Sunlight/UV Resistant
Cut/Abrasion Resistant
(unarmored)
Weld Flash Resistant - - - -
STANDARDS,AGENCY AND ENVIRONMENTAL COMPLIANCE          
UL
ANSI
CSA
CE
NEC® Article 727 Article 727 Article 727 Article 727 Article 727 Article 727
NFPA
IEC
RoHS2
REACH

 

STANDARDS, AGENCY AND ENVIRONMENTAL COMPLIANCE:

stard58.jpg

key:

  • - Not Applicable
  • √ Featured
  • ★ Cost Competitive Custom Options Available

 

  • Control
  • Power
  • Instrumentation
  • UL listed and approved for CE Mark
  • No conduit required means cost savings
  • Versatile - suitable for use in Class I, Div 2 areas
  • Saves space
  • Wet location use
  • Cold bend, impact and crush resistant
  • Flame resistant, exposed run and
    direct burial options available
  • Oil, chemical, sunlight, cut and
    weld flash resistant options available
  • Connectivity, low power sensors,
    instruments and control components
  • Factory floor automation equipment
  • Material handling
  • Transducers
  • Variable Frequency Drives (VFD)
nwi_direct.jpg nwi_express.jpg

 

 ITC-GPITC-GP(ER)ITC-RSITC-RS(ER)ITC-RS(ER)ITC-ExtremeITC -DB
General
Purpose
General
Purpose
Exposed
Run
Rugged
Service
Rugged
Service/
Exposed
Run
Direct
Burial/
Exposed
Run
ExtremeDirect Burial
INSULAT ED CONDUCTORS              
Conductor Count 2 or more 2 or more 2 or more 2 or more 2 or more 2 or more 2 or more 2 or more
AWG (mm2)t 22-12
(.325-3.31)
22-12
(.325-3.31)
22-12
(.325-3.31)
22-12
(.325-3.31)
22-12
(.325-3.31)
22-12
(.325-3.31)
22-12
(.325-3.31)
22-12
(.325-3.31)
Stranding-Minimum and
Maximum Diameter of
individual strands AWG in
inches (mm)
Material ETFE,ECTFE,
FEP,SRPVC
XLPE PVC PVC Nylon XLPE PVC Nylon XLPE PVC Nylon
Insulation
Wall Thickness
AWG Inches (mm)
22-20 .009
(0.23)
19-15 .009
(0.23)
14-12 .012
(0.30)
All AWG sizes
.020 (0.51)
22-20.012
(0.30)
19-15.015(0.38)
14-12 .020
(0.51)
22-20.015
(.38)
19-15.015
(.38)
14-12.015
(.38)
.005(.13)
.005(.13)
.005(.13)
All AWG sizes
.020 (0.51)
22-20.015
(.38)
19-15.015
(.38)
14-12.015
(.38)
.005(.13)
.005(.13)
.005(.13)
All AWG sizes
.020 (0.51)
22-20.015
(.38)
19-15.015
(.38)
14-12.015
(.38)
.005(.13)
.005(.13)
.005(.13)
OVERALL CABLING                
Fillers
Shielding
Armoring
Wraps
Strength Members
OUTER JACKET                
Material PVC, TPE PVC, TPE PVC, TPE PVC, TPE PVC, TPE PVC, TPE PVC, TPE PVC, TPE
Color
Overall OD inches
(mm)
Dependent on
construction
Dependent on
construction
Dependent on
construction
Dependent on
construction
Dependent on
construction
Dependent on
construction
Dependent on
construction
Dependent on
construction
ELECTRICAL                
DC Resistance UL 2250,
tables
11.1&11.2
UL 2250,
tables
11.1&11.2
UL 2250,
tables
11.1&11.2
UL 2250,
tables
11.1&11.2
UL 2250,
tables
11.1&11.2
UL 2250,
tables
11.1&11.2
UL 2250,
tables
11.1&11.2
UL 2250,
tables
11.1&11.2
Ampacity 5 amp max 5 amp max 5 amp max 5 amp max 5 amp max 5 amp max 5 amp max 5 amp max