NORTHWIRE RIG cables are designed and built to UL 1309, IEEE 1580, IEEE 45, and CSA C22.2 No. 245 standards, for use in marine environments, on offshore and fixed oil drilling rigs, aboard marine vessels, and on fixed or floating offshore structures.
These ruggedly-built cables are designed for low power distribution, control wiring and instrumentation. A wide range of sizes, constructions and ratings are available.
| |
Insulation Type |
Cold Temp. Rating Stationary/ Bend/ Impact |
Available Conductor Sizes |
Cabling Options |
| PVC Jacketed - minus 25°C construction |
|
|
|
|
| NORTHWIRE RIG 300 T |
T - PVC |
- 25°C/-25°C/-25°C |
AWG 16-22 |
go to specification |
| NORTHWIRE RIG 300 T/N |
T/N - PVC/Nylon |
- 25°C/-25°C/-25°C |
AWG 16-22 |
go to specification |
| |
|
|
|
|
Available Construction Options:
Cabling
- Non-Paired Multiconductor
- Individual Twisted Pairs
- Individual Triads
Armor
- Unarmored
- Inner sheath, tinned copper braid armor, outer jacket
- Inner sheath, bronze braid armor, outer jacket
Shielding
- Non-shielded
- Overall Foil Shield with Drain Wire
- Overall braided shield, overall foil, drain wire
- Individual foil-shielded pairs/triads, drain wires, overall foil with drain
- Individual foil-shielded pairs/triads, drain wires, overall foil and braid with drain *
Ground Wire
- No ground wire
- Green/Yellow ground wire
- Green ground wire
- White ground wire
|
For detailed specifications and pricing, please contact Northwire
Phone + 715-294-2121 (M-F 8:00am – 4:30pm Central Time)
Toll free 1-800-468-1516
email: CableInfo@northwire.com
|