ORDER TOLL-FREE
1-800-468-1516

Northwire Direct

Northwire Express Read more about Northwire Express

110 Prospect Way
Osceola, Wisconsin, 54020
715.294.2121
Fax:715.294.3727
cableinfo@ northwire.com

CableGram
Sign up to Receive Northwire's CableGram
For Email Marketing you can trust

ISO 9001:2008



Availability
Shipped from stock in 15 days.

Customs
Northwire specializes in Custom Technical Cable. Custom designs, materials, lengths, legends, logos, colors and special constructions are readily available. Ask for a free analysis and our no-risk prototyping program.
Get the Cable you want, Click here

Home >> Products/Services >> Product By Brand >> Profibus PA >> Specifications
Products/Services  
Profibus PA Profibus

DataCELLField

Rugged Bus Cables for Profibus PA Process Automation Networks
 
Specifications Overview Additional information Overview
UL ITC/PLTC-ER
CSA CMX-OUTDOOR-CMG
Cable example
Cable example3
CABLE TYPE
Profibus PA ISA/ANSI 50.02
 
UL ITC/PLTC-ER, CSA CMX-OUTDOOR,CMG
Physical Characteristics
Specification
Geometry
Individually shielded twisted pairs - overall shield - see part number table
Pair shield type
Aluminum/polyester foil - 100% coverage
Overall shield
Aluminum/polyester foil - 100% coverage
 
or 60% TC braid over AL/polyester foil - see part number table
Drain wire
with 18 AWG pairs, 20 AWG 7 strand TC
Foamed polypropylene tape wrap for easy jacket stripping  
Cable outside diameter
See part number table
Jacket marking
Northwire Inc. [P/n here] DataCELL® FOUNDATION fieldbus™ H1 (UL) ITC-ER 18 AWG/xSTP 105°C E195601 SUNLIGHT RESISTANT -40C or PLTC-ER 105°C or AWM 105°C 600V or CSA CMX-OUTDOOR-CMG LL54185 105°C or CSA AWM I/II A/B 105°C 600V FT4 or IEC 332 CE
Jacket material
oil, sunlight, water resistant PVC
Pair Conductor size
18 AWG 19 strand TC
Colors
See part number table
Temperature Rating
-40C to +105C
Electrical Characteristics
Impedance at fr (31,25 kHz) per FF-844
100 Ω ± 20 Ω
Maximum attenuation at 1.25fr (39kHz) per FF-844
3.0 dB/km
Max, DC resistance per conductor @20°C
23.5 Ω/km
Nominal DC resistance per conductor @20°C
for 18 AWG
21.4 Ω/km
Max, DC resistance for drain wire @20°C per UL 1581
36.7 Ω/km
Wire to shield capacitive unbalance
4 pF/M Max
Wire twists per M
18-22
Minimum bend radius
10 x Cable O.D.