Profibus DP Cables
| Part Number | Description |
| FPLTC222-005 | PROFIBUS DP Bus Cable Type A PLTC |
| FITC222-003 | PROFIBUS DP Bus Cable Type A ITC/PLTC-ER |
| FAWM222-062 | PROFIBUS DP Bus Cable Type A with PUR jacket |
PROFIBUS DP Bus Cable Type A PLTC |
||
![]() |
![]() |
|
| Cable Type |
PROFIBUS DP Type A, UL Listed PLTC
|
|
| Part Number |
FPLTC222-005
|
|
| Physical Characteristics |
Specification
|
|
| Geometry |
1 Shielded Twisted Pair
|
|
| Shield Type |
60% min TC Braid Over Aluminum/Polyester Foil – 100% coverage
|
|
| Drain Wire |
22 AWG 7 Strand TC
|
|
| Cable Outside Diameter |
0.335" Nominal
|
|
| Jacket Marking/Agency Approvals |
Northwire Inc. DataCELL FIELD - PROFIBUS DP FPLTC222-005 (UL) 22 AWG/2 PLTC 75C Sunlight Resistant E90625 or AWM 80C 300V or CSA CMX-Outdoor-CMG LL54185 75C or CSA AWM I/II A/B 80C 300V FT4
|
|
| Pair Conductor Size |
22 AWG 19 Strand Tinned Copper
|
|
| Pair Conductor O.D. |
0.110" Nominal
|
|
| Colors |
Red, Green
|
|
| Fillers |
Extruded PVC Filler Rods
|
|
| Outer Jacket Material |
PVC
|
|
| Outer Jacket Color |
Violet
|
|
| Electrical Characteristics |
|
|
| Impedance At Fr (3…20MHz) |
150 Ω Nominal
|
|
| Velocity of Propagation |
66%
|
|
| Dielectric Withstand Voltage |
1.5kVAC
|
|
| Maximum DC Resistance (Per Conductor) |
52.8 Ω/km
|
|
|
16.1 Ω/1000ft.
|
||
| Operating Capacitance |
9.0 pF/ft.
|
|
![]()