ORDER TOLL-FREE
1-800-468-1516

Northwire Direct

Northwire Express Read more about Northwire Express

110 Prospect Way
Osceola, Wisconsin, 54020
715.294.2121
Fax:715.294.3727
cableinfo@ northwire.com

CableGram
Sign up to Receive Northwire's CableGram
For Email Marketing you can trust

ISO 9001:2008



Availability
Shipped from stock in 15 days.

Customs
Northwire specializes in Custom Technical Cable. Custom designs, materials, lengths, legends, logos, colors and special constructions are readily available. Ask for a free analysis and our no-risk prototyping program.
Get the Cable you want, Click here

Home >> Products/Services >> Product By Brand >> MVC-800 >> FAWM226C-008 Specifications
Products/Services  
MVC Firewire
Firewire
RoHS logo

Northwire Vision

MVC - 800 & MVC - 800EL
 

Specifications Buy Now - Northwire Direct Overview Additional information Overview Overview Overview Additional information Overview Overview

Note: Click the Part Number for Specification
Part Number Description
FAWM226C-003 (MVC-800) FireWire Machine Vision Cable - Standard Length
FAWM226C-008 (MVC-800EL) FireWire Machine Vision Cable - Extended Length / Extended Life

 

DataCELL MVC-800EL FireWire Machine Vision Cable
Extended Length / Extended Life
MVC-800 FireWire Machine Vision Cable Cross section
 
   
CABLE TYPE DataCELL MVC-800EL
PART NUMBER FAWM226C-008
CONDUCTOR :  
Number of Conductors:
4/24 AWG, 2/22 AWG
Stranding: Fine stranded
OVERALL CABLING  
Fillers Non-wicking
Inner conductor colors 24AWG: Rd&Gn, Bu&Og  22AWG: Bk&Wt
INNER (PAIR) SHIELDS AL/polyester foil
  26AWG drain wires
OUTER SHIELD :  
Outer Shield Material: AL/polyester film
  TC braid overall - 90%
OUTER JACKET:  
Material TPE
Color dark green
DIMENSIONS  
Cable OD
0.285" nominal
   
MAXIMUM TEMPERATURE RATING +80°C
   
ELECTRICAL  
Max. Operating Voltage - UL: 30V
DataCELL MVC-800 meets or exceeds the electrical specifications per per IEEE 1394B:  
Characteristic Impedance  110 ohms ± 6 ohms (data pairs)
Capacitance 11.8 pF/ft nominal
Velocity of Propagation - Vp 75% min.
Propagation Delay 1.5 nS/ ft. max.
Conductor DC Resistance  
   
Mechanical  
Flex Life
>10 million cycles tick-tock, rolling and torsion
   
Standards and Agency Compliance  
APPLICABLE STANDARDS :  
NEC/(UL) Specification: UL recognized AWM
CSA Specification: CSA AWM I/II A/B
IEEE IEEE-1394b
RoHS RoHS compliant
FLAME TESTS:  
UL Flame Test  
CSA Flame Test CSA FT-1
PLENUM / NON-PLENUM : Non-Plenum