J1939
Cable Specifications

Type Part Number Construction
SAE J1939 General Specification
TF FJ1939182-001 18/2 Shielded w/Bare Copper Drain Outside Shield
TF FJ1939182-005 18/2 Shielded w/Tinned Copper Drain Inside Shield
TF FJ1939202-001 20/2 Shielded w/Bare Copper Drain Outside Shield
CR FJ1939182-002 18/2 Shielded w/Bare Copper Drain Outside Shield
CR FJ1939202-002 20/2 Shielded w/Bare Copper Drain Outside Shield


J1939 Cable

J1939 Cross Section

Cable Type DataCELL J1939 TF
Part Number FJ1939202-001
Conductors 2+Drain
No. of Pairs 1 Twisted Pair
Total No. of Connectors 3
AWG 20
Metric  
Stranding 19x32
Conductor Material Bare Copper
Insulation  
Material Cellular Cross-Linked Polyethylene
Nom. Wall Thickness 0.038" Nominal
Inner Conductor Diam. .113 ± 0.003"
Cable Construction  
Fillers Olefin Rods
Inner Conductor Colors Gn, Ye
Separator Al-Mylar Shield
Outer Shield  
Shield Material Al-Mylar-Al
Shield Type Foil
% Coverage 100%
Shield Drain Wire Drain Outside Shield
AWG 20
Stranding 19x32"
Conductor Material Bare Copper
Outer Jacket  
Material Thermoplastic Rubber
Color Black
Nom. Wall Thickness 0.035" Nominal
Mechanical  
Overall Outer Diameter 0.315 ± 0.005"
  8
Operating Temperature Range -40°C ... 125°C
Weight Per 1000 ft.  
Min. Installed Bending Radius Minimum 4 x Cable Diameter
Electrical  
Specific Line Delay Vp 75%
4.8 nS/M
Characteristic Impedance 120 Ohms @ 1MHz
Nom. Capacitance Conductor to Conductor 11.7 pF/Ft. Nominal
38.4 pF/M Nominal
Nom. Capacitance Conductor to Other Conductor and Shield 24.4 pF/Ft. Nominal
80 pF/M Nominal
Specific Conductor DC Resistance m Ohms/M @ 20° C 34.5
Specific Outer Shield DC Resistance m Ohms/M @ 20° C 30
Max Operating Voltage – UL 300

Applicable Standards and Agency Compliance

SAE J-1939/11
Environmental and Use  
Sunlight Resistance (Yes/No) Yes
Plenum/Non-Plenum  
Available Put-Ups Consult Factory