ORDER TOLL-FREE
1-800-468-1516

Northwire Direct

Northwire Express Read more about Northwire Express

110 Prospect Way
Osceola, Wisconsin, 54020
715.294.2121
Fax:715.294.3727
cableinfo@ northwire.com

CableGram
Sign up to Receive Northwire's CableGram
For Email Marketing you can trust

ISO 9001:2008



Availability
Shipped from stock in 15 days.

Customs
Northwire specializes in Custom Technical Cable. Custom designs, materials, lengths, legends, logos, colors and special constructions are readily available. Ask for a free analysis and our no-risk prototyping program.
Get the Cable you want, Click here

Home >> Products/Services >> Product By Brand >> J1939 >> FJ1939202-001 Specifications
Products/Services  
J1939 Example

DataCELL 1939
 

Specifications Overview Additional information Overview Overview Northwire Direct Overview Additional information Overview Overview

Note: Click the Part Number for Specification
Type Part Number Construction
SAE J1939 General Specification
TF FJ1939182-001 18/2 shielded w/Bare Copper Drain outside shield
TF FJ1939182-005 18/2 shielded w/Tinned Copper Drain inside shield
TF FJ1939202-001 20/2 shielded w/Bare Copper Drain outside shield
CR FJ1939182-002 18/2 shielded w/Bare Copper Drain outside shield
CR FJ1939202-002 20/2 shielded w/Bare Copper Drain outside shield


J1939 Cable

J1939 Cross Section

Specifications  
   
Cable Type DataCELL 1939TF™
Part Number FJ1939202-001
   
Conductors 2+drain
No. of pairs 1 twisted pair
Total no. of connectors 3
AWG 20
metric  
Stranding 19x32
Conductor Material Bare Copper
   
Insulation
 
Material Cellular Cross-linked Polyethylene
Nom. wall thickness 0.038" nominal
Inner Conductor Diam. .113 ± 0.003"
   
Cable Construction  
Fillers Olefin Rods
Inner conductor colors Gn, Ye
Separator Al-Mylar shield
   
Outer Shield  
Shield Material Al-Mylar-Al
Shield Type Foil
% coverage 100%
   
Shield Drain Wire
Drain Outside Shield
AWG 20
Stranding 19x32"
Conductor Material Bare Copper
   
Outer Jacket  
Material Thermoplastic Rubber
Color Black
Nom. Wall thickness 0.035" nominal
   
Mechanical  
Overall outer diameter 0.315 ± 0.005"
  8
   
Operating temperature range -40°C ... +125°C
weight per 1000 ft.  
Min. installed bending radius minimum 4 x cable diameter
   
Electrical  
Specific Line Delay Vp 75%
4.8 nS/M
Characteristic Impedance 120Ω @ 1MHz
   
Nom. Capacitance conductor to conductor 11.7 pF/Ft nominal
38.4 pF/M nominal
   
Nom. Capacitance conductor to other conductor & shield 24.4 pF/Ft. nominal
80 pF/M nominal
   
Specific Conductor DC resistance mΩ/M @ 20° C 34.5
   
Specific outer shield DC resistance mΩ/M @ 20° C 30
   
Max operating voltage - UL 300
   
Applicable Standards & Agency Compliance  
   
Standards  
SAE J-1939/11
   
Environmental & Use  
Sunlight Resistance (yes/no) yes
Plenum/non-plenum  
   
Available Put-ups Consult Factory
(state +/- lengths)