Products/Services  
J1939 Example

DataCELL 1939
 

Specifications Overview Additional information Overview Overview

Note: Click the Part Number for Specification
Type Part Number Construction
SAE J1939 General Specification
TF FJ1939182-001 18/2 shielded w/Bare Copper Drain outside shield
TF FJ1939182-005 18/2 shielded w/Tinned Copper Drain inside shield
TF FJ1939202-001 20/2 shielded w/Bare Copper Drain outside shield
CR FJ1939182-002 18/2 shielded w/Bare Copper Drain outside shield
CR FJ1939202-002 20/2 shielded w/Bare Copper Drain outside shield

18/2 shielded w/Drain Specification

 J1939 Cable J1939 Cross Section
Specifications  
   
Cable Type DataCELL 1939CR™
Part Number FJ1939182-002
   
Conductors 2+drain
No. of pairs 1 twisted pair
Total no. of connectors  
AWG 18
metric  
Stranding 16x30 AWG
Conductor Material Bare Copper
   
Insulation
 
Material Cellular Cross-linked Polyethylene
Nom. wall thickness 0.40" nominal
Inner Conductor Diam. .128 ± 0.003"
   
Cable Construction  
Fillers Olefin Rods
Inner conductor colors Gn, Ye
Separator Al-Mylar shield
   
Outer Shield  
Shield Material Al-Mylar-Al
Shield Type Foil
% coverage 100%
   
Shield Drain Wire
Drain Outside Shield
AWG 18
Stranding 16x30 AWG
Conductor Material Bare Copper
   
Outer Jacket  
Material High-performance Elastomer
Color Black
Nom. Wall thickness 0.040" nominal
   
Mechanical  
Overall outer diameter 0.350 ± 0.015"
  8.89
   
Operating temperature range -40°C ... +125°C
weight per 1000 ft.  
Min. installed bending radius minimum 4 x cable diameter
   
Electrical  
Specific Line Delay Vp 75%
4.8 nS/M
Characteristic Impedance 120Ω @ 1MHz
   
Nom. Capacitance conductor to conductor 11.7 pF/Ft nominal
38.4 pF/M nominal
   
Nom. Capacitance conductor to other conductor & shield 24.4 pF/Ft. nominal
80 pF/M nominal
   
Specific Conductor DC resistance mΩ/M @ 20° C 23
   
Specific outer shield DC resistance mΩ/M @ 20° C 25
   
Max operating voltage - UL 300
   
Applicable Standards & Agency Compliance  
   
Standards  
SAE J-1939/11
   
Environmental & Use  
Sunlight Resistance (yes/no) no
Plenum/non-plenum  
   
Available Put-ups Consult Factory