Northwire ITC-GP – Non-shielded, Non-paired
UL Listed ITC/PLTC General-Purpose
- Also CSA CMX-Outdoor-CMG
- High-grade black PVC outer jacket, PVC insulated conductors
- Rugged duty cable for factory floor instrumentation and controls
- UV and water resistant; suitable for outdoor use
- Available factory-direct from immediate stock - no minimums
|
Part Number
|
AWG
|
No. of Conductors
|
Overall O.D. Inches
|
Nominal Insulated Conductor O.D. In.
|
Stranding
|
Fillers
|
Weight #/
1000 ft. |
|
FITC223-01D
|
22
|
3
|
0.190"
|
0.050
|
7x.0096"TC
|
None
|
22.8
|
|
FITC224-01D
|
22
|
4
|
0.205"
|
0.050
|
7x.0096"TC
|
None
|
26.8
|
|
FITC225-01D
|
22
|
5
|
0.220"
|
0.050
|
7x.0096"TC
|
Poly
|
31.3
|
|
FITC226-01D
|
22
|
6
|
0.235"
|
0.050
|
7x.0096"TC
|
Poly
|
35.8
|
|
FITC203-01D
|
20
|
3
|
0.210"
|
0.059
|
7x.0121"TC
|
None
|
28.9
|
|
FITC204-01D
|
20
|
4
|
0.230"
|
0.059
|
7x.0121"TC
|
None
|
35.1
|
|
FITC205-01D
|
20
|
5
|
0.245"
|
0.059
|
7x.0121"TC
|
Poly
|
41.2
|
|
FITC206-01D
|
20
|
6
|
0.265"
|
0.059
|
7x.0121"TC
|
Poly
|
47.7
|
|
FITC183-01D
|
18
|
3
|
0.235"
|
0.070
|
16x30TC
|
None
|
37.2
|
|
FITC184-01D
|
18
|
4
|
0.255"
|
0.070
|
16x30TC
|
None
|
45.4
|
|
FITC185-01D
|
18
|
5
|
0.270"
|
0.070
|
16x30TC
|
Poly
|
53.6
|
|
FITC186-01D
|
18
|
6
|
0.305"
|
0.070
|
16x30TC
|
Poly
|
66.1
|
Northwire ITC-GP Shielded, Non-Paired
UL-listed ITC/PLTC General-Purpose with braid and foil overall shield
- Also CSA CMX-Outdoor-CMG
- High-grade black PVC outer jacket, PVC insulated conductors
- Rugged duty cable for factory floor instrumentation and controls
- UV and water resistant; suitable for outdoor use
- Available factory-direct from immediate stock – no minimums
|
Part Number
|
AWG
|
No. of Conductors
|
Overall O.D. Inches
|
Nominal Insulated Conductor O.D. In.
|
Stranding
|
Fillers
|
Weight #/
1000 ft. |
|
FITC223-02D
|
22
|
3
|
0.210"
|
0.050
|
7x.0096"TC
|
None
|
23.7
|
|
FITC224-02D
|
22
|
4
|
0.225"
|
0.050
|
7x.0096"TC
|
None
|
28.0
|
|
FITC225-02D
|
22
|
5
|
0.240"
|
0.050
|
7x.0096"TC
|
Poly
|
32.4
|
|
FITC226-02D
|
22
|
6
|
0.255"
|
0.050
|
7x.0096"TC
|
Poly
|
37.0
|
|
FITC203-02D
|
20
|
3
|
0.235"
|
0.059
|
7x.0121"TC
|
None
|
35.9
|
|
FITC204-02D
|
20
|
4
|
0.255"
|
0.059
|
7x.0121"TC
|
None
|
43.3
|
|
FITC205-02D
|
20
|
5
|
0.270"
|
0.059
|
7x.0121"TC
|
Poly
|
49.1
|
|
FITC206-02D
|
20
|
6
|
0.300"
|
0.059
|
7x.0121"TC
|
Poly
|
60.2
|
|
FITC183-02D
|
18
|
3
|
0.250"
|
0.070
|
16x30TC
|
None
|
42.4
|
|
FITC184-02D
|
18
|
4
|
0.280"
|
0.070
|
16x30TC
|
None
|
54.9
|
|
FITC185-02D
|
18
|
5
|
0.305"
|
0.070
|
16x30TC
|
Poly
|
66.2
|
|
FITC186-02D
|
18
|
6
|
0.330"
|
0.070
|
16x30TC
|
Poly
|
75.6
|
| General Specifications | |
| Conductor Material | Tinned Copper |
| Insulation Material | Semi Rigid PVC to AWM 10002 |
| Insulation Nom./Min. Thickness | 0.009"/0.008" |
| Fillers | Fibrillated Polypropylene Where Used |
| Inner Conductor Colors | Bu, Bn, Bk, (4)Wt, (5)Gy, (6)Pk, See Color Table 1 |
| Separator | Tissue Paper |
| Shielded Version | |
| Shield Material | 60% Min. 36 AWG TC Braid, 100% Mylar® Foil |
| Shield Type – Shielded Version | Braid Over Foil |
| Outer Jacket | |
| Material | PVC |
| Color | Black |
| Nom. Wall Thickness | 0.035" |
| Minimum Wall Thickness | 0.030" |
| Mechanical | |
| Min. Installed Bending Radius | 10 x Nominal O.D. |
| Electrical | |
| Max Operating Voltage – UL | 300V |
| Dielectric Withstand Voltage | 1.5kVAC |
| Applicable Standards and Agency Compliance | |
| Standards | |
| UL | UL 2250 ITC |
| UL 13 PLTC | |
| UL AWM 2517 | |
| CSA | AWM I/II A/B FT4 |
| CMX-OUTDOOR-CMG | |
| Flame Retardant FT4 | |
| C22.2 No. 210 | |
| C22.2 No. 214 | |
| Other | IEC 332-3 Flame Rated |
| Complies with NEC 725 and 727 | |
| RoHS | |
| Environmental and Use | |
| Operating Temperature Range | –30°C ..+105°C |
| Hazardous location | Class I, Div. 2 |
| Sunlight Resistant (yes/no) | Yes |
| Plenum/Non-Plenum | Non-Plenum |
| Available Put-ups | |
| Put-Ups | No Minimum Length Requirement |
| Continuous Lengths, Specfied Put-Ups | Contact Factory |