header.gif


ORDER TOLL-FREE
1-800-468-1516

Northwire Direct

Northwire Express

110 Prospect Way
Osceola, Wisconsin, 54020
715.294.2121
Fax:715.294.3727
cableinfo@ northwire.com

Environmentally Wired
Environmentally Wired

ISO 9001:2000



Availability
Shipped from stock in 15 days.

Customs
Northwire specializes in Custom Technical Cable. Custom designs, materials, lengths, legends, logos, colors and special constructions are readily available. Ask for a free analysis and our no-risk prototyping program.
Get the Cable you want, Click here

Home >> Products/Services >> Product By Brand >> ITC/PLTC >> Part Numbers & Specifications
Products/Services  

ITC PLTC

ITC PLTC
 
Part Numbers & Specifications Buy Now - Northwire DirectSelection Guide Overview

Northwire Direct
ITC 4 Wire

Northwire ITC-GP - non-shielded, non-paired

UL Listed ITC/PLTC General-purpose 
•  Also CSA CMX+Outdoor+CMG
•  High-grade black PVC outer jacket, PVC insulated conductors 
•  Rugged duty cable for factory floor instrumentation and controls
•  UV and water resistant; suitable for outdoor use
•  Available factory-direct from immediate stock - no minimums
 

Part Number
AWG
No. of Conductors
Overall OD inches
Nominal insulated conductor O.D. in.
Stranding
Fillers
Weight #/1000 ft.
FITC223-01D
;
22
3
0.190"
0.050
7x.0096"TC
none
22.8
FITC224-01D
;
22
4
0.205"
0.050
7x.0096"TC
none
26.8
FITC225-01D
;
22
5
0.220"
0.050
7x.0096"TC
poly
31.3
FITC226-01D
;
22
6
0.235"
0.050
7x.0096"TC
poly
35.8
FITC203-01D
;
20
3
0.210"
0.059
7x.0121"TC
none
28.9
FITC204-01D
;
20
4
0.230"
0.059
7x.0121"TC
none
35.1
FITC205-01D
;
20
5
0.245"
0.059
7x.0121"TC
poly
41.2
FITC206-01D
;
20
6
0.265"
0.059
7x.0121"TC
poly
47.7
FITC183-01D
;
18
3
0.235"
0.070
16x30TC
none
37.2
FITC184-01D
;
18
4
0.255"
0.070
16x30TC
none
45.4
FITC185-01D
;
18
5
0.270"
0.070
16x30TC
poly
53.6
FITC186-01D
;
18
6
0.305"
0.070
16x30TC
poly
66.1

 

Northwire Direct
ITC 4 Wire with Braid

Northwire ITC-GP shielded, non-paired

UL Listed ITC/PLTC General-purpose with braid and foil overall shield
•  Also CSA CMX+Outdoor+CMG
•  High-grade black PVC outer jacket, PVC insulated conductors 
•  Rugged duty cable for factory floor instrumentation and controls
•  UV and water resistant; suitable for outdoor use
•  Available factory-direct from immediate stock - no minimums
>> Click Here to Order from NorthwireDirect <<

Part Number
AWG
No. of Conductors
Overall OD inches
Nominal insulated conductor O.D. in.
Stranding
Fillers
Weight #/1000 ft.
FITC223-02D
;
22
3
0.210"
0.050
7x.0096"TC
none
23.7
FITC224-02D
;
22
4
0.225"
0.050
7x.0096"TC
none
28.0
FITC225-02D
;
22
5
0.240"
0.050
7x.0096"TC
poly
32.4
FITC226-02D
;
22
6
0.255"
0.050
7x.0096"TC
poly
37.0
FITC203-02D
;
20
3
0.235"
0.059
7x.0121"TC
none
35.9
FITC204-02D
;
20
4
0.255"
0.059
7x.0121"TC
none
43.3
FITC205-02D
;
20
5
0.270"
0.059
7x.0121"TC
poly
49.1
FITC206-02D
;
20
6
0.300"
0.059
7x.0121"TC
poly
60.2
FITC183-02D
;
18
3
0.250"
0.070
16x30TC
none
42.4
FITC184-02D
;
18
4
0.280"
0.070
16x30TC
none
54.9
FITC185-02D
;
18
5
0.305"
0.070
16x30TC
poly
66.2
FITC186-02D
;
18
6
0.330"
0.070
16x30TC
poly
75.6

 

General Specifications
Conductor material tinned copper
Insulation material Semi rigid PVC to AWM 10002
Insulation nom./ min. thickness 0.009"/0.008"
Fillers fibrillated polypropylene where used
Inner conductor colors Bu, Bn, Bk, (4)Wt, (5)Gy, (6)Pk, see <color table 1>
Separator tissue paper
Shielded version:
Shield material 60% min. 36 AWG TC braid, 100% Mylar foil
Shield type - shielded version braid over foil
Outer Jacket
Material PVC
Color Black
Nom. wall thickness 0.035"
Minimum wall thickness 0.030"
Mechanical
Min. installed bending radius 10 x nominal OD
Electrical
Max operating voltage - UL 300V
Dielectric Withstand Voltage 1.5kVAC
Applicable Standards and Agency Compliance
Standards
UL UL 2250 ITC
UL 13 PLTC
UL AWM 2517
CSA AWM I/II A/B FT4
CMX+OUTDOOR+CMG
Flame retardant FT4
C22.2 No. 210
C22.2 No. 214
Other IEC 332-3 flame rated
Complies with NEC 725 and 727
Environmental and Use
Operating temperature range  –30°C ..+105°C
Hazardous location Class I, div. 2
Sunlight Resistant (yes/no) yes
Plenum/non-plenum non plenum
Available Put-ups
Put-ups no minimum length requirement
Continuous lengths, specfied put-ups contact factory