Custom-Configured ITC/PLTC Cable for Exposed Run Applications
Instrument and control wiring – for factory-floor automation equipment, material handling, sensors and transducers, process controls and other applications – is cost-effective using UL listed* Northwire ITC/PLTC cable. Choose from six basic cable platforms with millions of possible custom-configured options.
Northwire ITC/PLTC Cable offers a variety of advantages including:
- Low-cost installation. Takes advantage of the ITC/PLTC-Exposed Run amendment to the NEC. Learn more >>
- Versatility Northwire ITC/PLTC cables are approved for Class 1, Div. 2 hazardous areas. The Northwire ITC-GP aluminum-armored version is suitable for Div. 1 areas. Six product platforms offer a myriad of attributes to suit many applications and operating environments.
- Designed for wet locations No conduit means there’s no place to collect water.
- Inherently smaller Limited to 150 volts and 5 amp maximum current applications, the cable becomes inherently smaller and less expensive than traditional Tray Cable.
- Connectivity Suitable for modern low power sensors, instruments and other control components. Small size is also better suited for adding connectors.
- Millions of possibilities Six basic platforms with options for paired or triad instrumentation cable or non-paired control cable, with or without ground wires, shield options, conductor color options, insulation options and more.

Northwire ITC-GP cable is now available Factory-Direct from stock in 15 days <click here> for available part numbers.
Millions of variations of Northwire ITC cables can be quickly configured, quoted, and shipped in days.
| Six Platforms to Build On |
 |
General Purpose. For lowest cost or if aluminum armor is required. |
 |
General Purpose/Exposed Run. For lower installed cost indoors where Exposed Run rated cabling is desired. |
 |
Rugged Service. Tougher TPE-jacketed cable for difficult manufacturing environments, particularly in presence of weld flash and/or oil cutting fluids. Also well suited for abrasion resistance. |
 |
Rugged Service/Exposed Run. A tougher TPE-jacketed cable with excellent abrasion and oil resistance. |
 |
Direct Burial/Exposed Run. For use outdoors and in direct burial applications where maximum crush resistance is needed and Exposed Run can be used. |
 |
For extreme environments such as very low temperatures and where high cut resistance and/or oil resistance is needed. |
*Northwire ITC cable is UL listed ITC per NEC article 727 and PLTC per NEC article 725, and AWM. Also CSA listed AWM I/II, A/B, FT-4; CSA recognized CMX-Outdoor-CMG.