| UL ITC/PLTC-ER |
|
| CSA CMX-OUTDOOR-CMG |
|
|
|
| CABLE TYPE |
FOUNDATION fieldbusTM H1 Type "A" |
| |
UL ITC/PLTC-ER, CSA CMX-OUTDOOR,CMG |
|
|
| Physical Characteristics |
Specification |
| Geometry |
Individually shielded twisted pairs - overall shield - see part number table |
| Pair shield type |
Aluminum/polyester foil - 100% coverage |
| Overall shield |
Aluminum/polyester foil - 100% coverage |
| |
or 60% TC braid over AL/polyester foil - see part number table |
| Drain wire |
with 18 AWG pairs, 20 AWG 7 strand TC |
|
with 16 AWG pairs, 18 AWG 7 strand TC |
| Foamed polypropylene tape wrap for easy jacket stripping |
|
| Cable outside diameter |
See part number table |
| Jacket marking |
Northwire Inc. [P/n here] DataCELL® FOUNDATION fieldbus™ H1 (UL) ITC-ER 18 (or 16) AWG/xSTP 105°C E195601 SUNLIGHT RESISTANT -40C or PLTC-ER 105°C or AWM 105°C 600V or CSA CMX-OUTDOOR-CMG LL54185 105°C or CSA AWM I/II A/B 105°C 600V FT4 or IEC 332 CE |
| Jacket material |
oil, sunlight, water resistant PVC |
| Pair Conductor size |
18 or 16 AWG 19 strand TC |
| Colors |
See part number table |
| Temperature Rating |
-40C to +105C |
| Electrical Characteristics |
|
| Impedance at fr (31,25 kHz) per FF-844 |
100 Ω ± 20 Ω |
| Maximum attenuation at 1.25fr (39kHz) per FF-844 |
3.0 dB/km |
| Max, DC resistance per conductor @20°C per FF-844 |
23.5 Ω/km |
| Nominal DC resistance per conductor @20°C |
|
| for 18 AWG |
21.4 Ω/km |
| for 16 AWG |
13.6 Ω/km |
| Max, DC resistance for drain wire @20°C per UL 1581 |
36.7 Ω/km |
| Wire to shield capacitive unbalance |
4 pF/M Max |
| Wire twists per M |
18-22 |
| Minimum bend radius |
10 x Cable O.D. |