header.gif


ORDER TOLL-FREE
1-800-468-1516

Northwire Direct

Northwire Express

110 Prospect Way
Osceola, Wisconsin, 54020
715.294.2121
Fax:715.294.3727
cableinfo@ northwire.com

Environmentally Wired
Environmentally Wired

ISO 9001:2000



Availability
Shipped from stock in 15 days.

Customs
Northwire specializes in Custom Technical Cable. Custom designs, materials, lengths, legends, logos, colors and special constructions are readily available. Ask for a free analysis and our no-risk prototyping program.
Get the Cable you want, Click here

Home >> Products/Services >> Product By Brand >> EnduroFLEX ERP Specifications
Products/Services  
EnduroFLEX ERP example

EnduroFlex ERP

 
 
Specifications Buy Now - Northwire Direct Overview Additional information Overview Overview
EnduroFLEX ERP TC-Exposed Run / STOOW 600V
Northwire
Part Number
AWG/
Conductors
Stranding/
cond. OD
Nominal insulation
wall thickness

Outer
jacket wall

Cable
O.D.
Max. Current
Amps
FTC83-001
8/3
7x19x29/0.302"
0.060" +- 0.005"
0.110"
0.870"
55
FTC84-001
8/4
7x19x29/0.302"
0.060" +- 0.005"
0.125"
1.00"
55
FTC103-001
10/3
105x30/0.227"
0.045" +- 0.005"
0.095"
0.680"
40
FTC104-001
10/4
105x30/0.227"
0.045" +- 0.005"
0.095"
0.750"
40
FTC123-001
12/3
65x30/0.202"
0.045" +- 0.005"
0.095"
0.625"
30
FTC124-001
12/4
65x30/0.202"
0.045" +- 0.005"
0.095"
0.690"
30
FTC143-001
14/3
41x30/0.177"
0.045" +- 0.005"
0.080"
0.545"
25
FTC144-001
14/4
41x30/0.177"
0.045" +- 0.005"
0.080"
0.600"
25
FTC163-001
16/3
26x30/0.132"
0.030" +- 0.005"
0.060"
0.390"
18
FTC164-001
16/4
26x30/0.132"
0.030" +- 0.005"
0.060"
0.423"
18
FTC183-001
18/3
16x30/0.122"
0.030" +- 0.005"
0.060"
0.410"
14
FTC184-001
18/4
16x30/0.122"
0.030" +- 0.005"
0.060"
0.450"
14

EnduroFLEX ERP Specifications
Conductor Material
BC–Bare Copper
Insulation Type / Material 8-14 AWG: THWN-2; 16-18 AWG: TFFN PVC / Nylon
Conductor Colors 1-Wh, 2-Bk, 3-Gn, 4-Rd
Fillers / Separator
Paper / Tissue paper
Outer Shield Unshielded
Outer Jacket Material / Color
Oil resistant PVC / Grey
Operating Temperature Range –40°C to +105°C (see UL spec below)
Max. Operating Voltage–UL
600V RMS
Dielectric Withstand Voltage 1500V AC applied for 1 min. *per NEC article 392.11
NEC / UL Specification
(UL) TC-ER 90°C dry, 75°C wet 600V Oil res I & II or STOOW -40..+105°C; sunlight
resistant, water resistant, UL 1277 recognized for Tray Cable - direct support
requirements, Complies with NFPA 79-2002 Exposed Run
UL Flame Test/ CSA Flame Test Meets UL Vertical Tray / FT-4