ORDER TOLL-FREE
1-800-468-1516

Northwire Direct

Northwire Express Read more about Northwire Express

110 Prospect Way
Osceola, Wisconsin, 54020
715.294.2121
Fax:715.294.3727
cableinfo@ northwire.com

CableGram
Sign up to Receive Northwire's CableGram
For Email Marketing you can trust

ISO 9001:2008



 

Availability
Shipped from stock in 15 days.

Customs
Northwire specializes in Custom Technical Cable. Custom designs, materials, lengths, legends, logos, colors and special constructions are readily available. Ask for a free analysis and our no-risk prototyping program.
Get the Cable you want, Click here

Home >> Products/Services >> Product By Brand >> ODVA DeviceNet PLTC Thin
Products/Services  
ODVA Thick

DataCELLField

ODVA™ DeviceNet™ Cables
 
Specifications Buy Now - Northwire Direct Overview Additional information Overview

Note: Click the Part Number for Specification
Part Number
Construction
FPLTC154C-001 ODVA Thick
FCL224C-007 ODVA Thin
FPLTC224-006 Special PLTC Thin

ODVA Special PLTC Thin
   
PLTC thin
CABLE TYPE
DeviceNet TM Special PLTC Thin Cable
Version
Special "Thin" PLTC, AWM
PART NUMBER
FPLTC224-006
Network Standard
ODVA DeviceNet
   
Data Pair Specifications
Physical Characteristics
Specification
Conductor pair size
22 AWG 19 strand TC
Insulation diameter
0.088" ± .005"
Colors
Bu, Wh
Pair twist / ft.
approx. 3
Tape shield over pair
Al/polyester foil out
Electrical Characteristics
Specification
Impedance
120 Ω ± 10%
Propagation delay
1.36 ns/ ft. (nom)
Capacitance between conductors
11.33pF/ ft @ 1KHz
Capacitance between one conductor and other conductor connected to shield
24pF/ ft @ 1KHz
Capacitive unbalance
1200 pF/ 1000 ft.maximum
DCR - @ 20° C
18.1 Ω/1000 ft.
Attenuation 
@ 125 kHz:  0.29 dB/100ft. max.
 
@ 500 kHz:  0.50 dB/100ft. max.
 
@ 1 MHz:  0.70 dB/100ft. max.
DC Power Pair Specifications
Physical Characteristics
Specification
Conductor pair size
22 AWG 19 strand TC
Insulation diameter
0.050" ± .002"
Colors
Rd, Bk
Pair twist / ft.
approx. 3
Tape shield over pair
Al / polyester foil out
Electrical Characteristics
Specification
DCR - @ 20° C
18.1 Ω/1000 ft
General Specifications
Physical Characteristics
Specification
Geometry
2 shielded pairs, common axis w/ drain wire in center
Overall braid shield
65% minimum 36 AWG TC
Drain wire
22 AWG 19 strand TC
Outside diameter
0.300" ± .010"
Roundness
Radius delta less than 15% of 1/2 O.D.
Jacket marking
Northwire Inc. DataCELL® FIELD  DeviceNet™ Special PLTC Thin – FPLTC224-006 (UL) 22AWG/4 PLTC 75°C Sunlight Resistant E90625 or AWM 80°C 300V or CSA LL54185 AWM  I/II A/B 80°C 300V FT4
Electrical Characteristics
Specification
DCR (braid+tape+drain)
3.2 Ω/1000 ft nominal @ 20°C
Applicable Environmental Characteristics
Specification
Agency certifications (US and Canada)
NEC (UL) type PLTC or AWM;  CSA AWM
Flexure
Tested 2000 cycles minimum at 4.5" bend radius, 90 degrees, 2 lb. minimum pull force, 30 cycles per minute, tic-toc method
Bend raduis
20 x diameter (installation); 7 x diameter (fixed)
Operating ambient temperature
-20..+75°C
Storage temperature
-40..+85°C
Pull tension
65 Lb Maximum
Connector compatibility
Mini, Micro, Open
Topology compatibility
Trunk, drop