| Part Number |
Description |
| FAWM2822-005 |
Standard Camera Link Bulk Cable 28 AWG |
| FAWM2824-002 |
Power over Camera Link® Bulk Cable 28 AWG |
| Specifications and Technical Data |
DataCELL® Camera Link Machine Vision Cable |
|
 |
| Cable Type |
Power over Camera Link (PoCL) |
| Part Number |
FAWM2824-002 |
| Conductor |
|
| Number of Conductors |
11 Shielded Twisted Pair, 28 AWG |
| |
28/2 Non-Paired, Non-Shelded Power Conductors |
| Stranding |
19 Strand |
| Overall Cabling |
|
| Fillers |
Non-Wicking Poly |
| Inner Conductor Colors |
Pairs: Bk-Rd, Bk-Bu, Bk-Gn, Bk-Ye, Bk-Vi, Wh-Ye, Wh-Vi, Wh-Rd, Wh-Bu, Wh-Gn, Gy-Rd |
| |
Power: Rd, Rd |
| Inner (Pair) Shields |
AL/Polyester Foil |
| Drain Wires |
4-28 AWG 7 Strand TC Between Inner and Outer Shields |
| Outer Shield |
|
| Outer Shield Material |
AL/Polyester Foil |
| |
TC Braid Overall – 90% Min. |
| Outer Jacket |
|
| Material |
High-Performance TPE |
| Color |
Dark Green |
| Dimensions |
|
| Cable O.D. |
0.355" Nominal |
| Electrical |
|
| Max. Operating Voltage — UL |
30V |
| Characteristic Impedance |
100 Ohms ± 10 Ohms |
| Capacitance |
15.0 pF/ft ± 2 |
| Velocity of Propagation — Vp |
75% Min. |
| Propagation Delay |
1.5 nS/ ft. Max. |
| Conductor DC Resistance |
72 ohms/1000 ft. Max. |
| Physical |
|
| Flex life |
tested to exceed 19 million cycles on Northwire tick-tock flex test device |
| Maximum Temperature Rating |
+80°C |
| Standards and Agency Compliance |
|
| Conformance |
Meets the requirements of Appendices D and E (Power requirements and Specifications) of the Camera Link specification |
| NEC/(UL) Specification |
UL recognized AWM |
| CSA Specification |
CSA AWM I/II A/B |
| RoHS |
RoHS compliant |
| Plenum / Non-plenum |
Non-Plenum |
| Flame Test |
|
| UL Flame Test |
VW-1 |
| CSA Flame Test |
CSA FT-1 |